DocumentCode :
2190404
Title :
Research on the fsPB of Arbitrary Collimator Rotational Angle by Coordinate Transformation
Author :
Wang, Chao ; Li, Guoli ; Lin, Hui ; Jing, Jia ; Yan, Bing ; Sheng, Daning ; Xia, Baihua
Author_Institution :
Hefei Univ. of Technol., Hefei, China
fYear :
2009
fDate :
17-19 Oct. 2009
Firstpage :
1
Lastpage :
4
Abstract :
Based on the dose distribution results under the condition of vertical incident beam by finite-size Pencil Beam (fsPB) matrix model using Monte Carlo simulation, this paper introduces the means of coordinate transformation, which can transform the dose distribution from the condition of vertical incident to the arbitrary collimator rotational angel. The dose distribution results of test examples are compared with the simulation results of Electron-Gamma Shower (EGS), the effective and accuracy of the algorithm are proved.
Keywords :
Monte Carlo methods; collimators; dosimetry; radiation therapy; Monte Carlo simulation; arbitrary collimator rotational angle; coordinate transformation; dose distribution; electron-gamma shower; finite-size pencil beam matrix model; fsPB; vertical incident beam; Biomedical applications of radiation; Chaos; Colliding beam accelerators; Collimators; Educational institutions; Imaging phantoms; Interpolation; Monte Carlo methods; Skin; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering and Informatics, 2009. BMEI '09. 2nd International Conference on
Conference_Location :
Tianjin
Print_ISBN :
978-1-4244-4132-7
Electronic_ISBN :
978-1-4244-4134-1
Type :
conf
DOI :
10.1109/BMEI.2009.5305370
Filename :
5305370
Link To Document :
بازگشت