• DocumentCode
    2192158
  • Title

    Biomedical application of high sensitive synchrotron X-ray imaging techniques to assess the microstructures and function of hamster heart

  • Author

    Wu, Jin ; Takeda, Tohoru ; Lwin, Thet Thet ; Yuasa, Tetsuya ; Minami, Manabu ; Akatsuka, Takao

  • Author_Institution
    Univ. of Tsukuba, Ibaraki
  • fYear
    2007
  • fDate
    12-14 Oct. 2007
  • Firstpage
    55
  • Lastpage
    58
  • Abstract
    High sensitive synchrotron X-ray imaging techniques such as phase-contrast X-ray computed tomography with an X-ray interferometer (p-CT) and fluorescent X-ray computer tomography (FXCT) have been developed for biomedical researches. In this study, formalin fixed cardiac specimens of normal and cardiomyopathy hamsters were imaged to examine the feasibility of these imaging techniques. P-CT revealed the detailed morphological structures of heart such as myocardial density change, wall thickness and ventricular cavity, whereas FXCT demonstrated myocardial fatty acid metabolic impairment by using non-radioactive 1-127 labeled BMIPP. Even in younger 8-weeks-old cardiomyopathic hamster, the metabolic impairment was clearly revealed. Myocardial density and BMIPP uptake was analyzed quantitatively. Our results suggest these techniques have high sensitivity in density change and spatial resolution, and they are quite useful for myocardial biomedical research in small animals.
  • Keywords
    X-ray imaging; biomedical imaging; cardiology; computerised tomography; cardiomyopathy hamsters; fatty myocardial acid metabolic impairment; fluorescent X-ray computer tomography; hamster heart; heart microstructures; high sensitive synchrotron X-ray imaging techniques; myocardial density change; nonradioactive I-127 labeled BMIPP; phase-contrast X-ray computed tomography; ventricular cavity; wall thickness; Application software; Biomedical computing; Cardiology; Computed tomography; Fluorescence; Heart; Microstructure; Myocardium; Synchrotrons; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging, 2007. NFSI-ICFBI 2007. Joint Meeting of the 6th International Symposium on
  • Conference_Location
    Hangzhou
  • Print_ISBN
    978-1-4244-0949-5
  • Electronic_ISBN
    978-1-4244-0949-5
  • Type

    conf

  • DOI
    10.1109/NFSI-ICFBI.2007.4387686
  • Filename
    4387686