DocumentCode :
2195639
Title :
Method of current transformer metrological properties estimation for transformation of distorted currents
Author :
Kaczmarek, M.
Author_Institution :
Dept. of Instrum. Transformers & Electromagn. Compatibility, Tech. Univ. of Lodz, Lodz, Poland
fYear :
2012
fDate :
3-7 June 2012
Firstpage :
724
Lastpage :
726
Abstract :
During transformation of power frequency currents inductive current transformers (CTs) are characterized by precise, acceptable in accordance with their accuracy class, values of current errors and phase displacements. CTs catalogues do not specify metrological properties of transformation for distorted currents. The aim of the paper is to present a new method for evaluating the metrological parameters of CTs during transformation of distorted currents based on determined values of the composite errors / transformer correction factors.
Keywords :
current transformers; CT catalogues; composite errors; current transformer metrological properties estimation method; distorted currents; distorted currents transformation; metrological parameters; phase displacements; power frequency currents inductive current transformers; transformer correction factors; Inductive current transformer; composite error; distorted current; transformer correction factor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Modulator and High Voltage Conference (IPMHVC), 2012 IEEE International
Conference_Location :
San Diego, CA
Print_ISBN :
978-1-4673-1222-6
Type :
conf
DOI :
10.1109/IPMHVC.2012.6518847
Filename :
6518847
Link To Document :
بازگشت