Abstract
The present paper illustrates an experimental analysis on the comparative analysis of air-conditioning energy savings of different green roof applications based on experimental measurements. Tests were carried out on nine different green roof samples, involving three types of growth media (lava, arkalyte, pumice) matched with three sedum types (kamtchaticum, spurium, sexangulare). Temperature readings at the bases of each sample were recorded for 32 months continuously at every 15 minutes. The data was processed and the heat gain of a sample building with each green roof application was calculated theoretically. The energy consumption comparisons showed that the right selection of growth media and vegetation can yield significant energy savings for air-conditioning applications.
Keywords
air conditioning; energy conservation; energy consumption; roofs; structural engineering; air conditioning; building; energy conservation analysis; energy consumption; energy saving; green roof systems; Cities and towns; Cooling; Costs; Energy conservation; Energy consumption; Green buildings; Insulation; Temperature; Thermal pollution; Vegetation;
fLanguage
English
Publisher
ieee
Conference_Titel
Green Technologies Conference, 2010 IEEE
Conference_Location
Grapevine, TX
Print_ISBN
978-1-4244-5274-3
Electronic_ISBN
978-1-4244-5275-0
Type
conf
DOI
10.1109/GREEN.2010.5453802
Filename
5453802
Link To Document