• DocumentCode
    2198311
  • Title

    Comparison of unconventional inter-filtering methods to penalised-likelihood for space-invariant tomographs

  • Author

    Mustafovic, S. ; Thielemans, K.

  • Author_Institution
    PET Methods Group, Hammersmith Hosp., London, UK
  • Volume
    3
  • fYear
    2002
  • fDate
    10-16 Nov. 2002
  • Firstpage
    1691
  • Abstract
    Images reconstructed with iterative algorithms with conventional inter-iteration filtering as a method of regularisation have spatially varying resolution, which is also object dependent. Three different methods were previously proposed which overcome that problem. Here we compare these algorithms with inter-iteration filtering to penalised likelihood algorithms and in particular penalised likelihood with certainty based penalty (PLCB). We derive an analytic expression that relates the penalty term to the filter coefficients. The linearised local impulse response (LLIR) as well as noise properties present in these algorithms are nearly identical if this matching is performed. This is confirmed with simulations.
  • Keywords
    filtering theory; image reconstruction; iterative methods; positron emission tomography; certainty based penalty; filter coefficients; inter-filtering methods; inter-iteration filtering; iterative algorithms; linearised local impulse response; noise; penalised-likelihood; space-invariant tomographs; Filtering algorithms; Filters; Hospitals; Image reconstruction; Image resolution; Iterative algorithms; Iterative methods; Positron emission tomography; Space technology; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2002 IEEE
  • Print_ISBN
    0-7803-7636-6
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2002.1239649
  • Filename
    1239649