DocumentCode
2198650
Title
Application of a small field of view gamma camera based on a 5" PSPMT and crystal scintillator array for high resolution small animal cardiac imaging
Author
Goode, Allen R. ; Glover, David K. ; Watson, Denny D. ; Beller, George A. ; Riou, Laurent M. ; Lima, Ronaldo ; Hatada, Ken ; Ruiz, Mirta ; Kross, Brian ; Majewski, Stan ; Popov, Vladimir ; Smith, Mark F. ; Weisenberger, Andrew G. ; Welch, Benjamin ; Wojci
Author_Institution
Univ. of Virginia Health Svstem, Charlottesville, VA, USA
Volume
3
fYear
2002
fDate
10-16 Nov. 2002
Firstpage
1765
Abstract
We have built a small field-of-view gamma camera based on a 5" diameter Hamamatsu R3292 position sensitive photomultiplier tubes (PSPMT) and Nal(Tl) crystal for high resolution small animal imaging. The instrument was specifically developed for high performance cardiac imaging in rats and mice. Results of measurements in both mouse and rat models will be presented. Dynamic ECG-gated and static planar pinhole pet-fusion images of rat hearts were acquired allowing semi-quantitative and functional interpretation. Additionally, molecular imaging of neutrophil infiltration in a mouse model of myocardial post-ischemic inflammation vi-as performed. We demonstrate the utility of this high resolution instrument for molecular and functional cardiac imaging in small animal models a( heart rates of 250-600 bpm. The superior performance of this new camera will allow the noninvasive monitoring of radiolabeled molecular probes for assessing physiologic processes in the heart as well as other organ systems of small animals.
Keywords
cardiology; gamma-ray detection; photomultipliers; position sensitive particle detectors; single photon emission computed tomography; solid scintillation detectors; veterinary medicine; Hamamatsu R3292 position sensitive photomultiplier tubes; NaI(Tl) crystal; NaI:Tl; dynamic ECG-gated pinhole pet-fusion images; functional cardiac imaging; high performance cardiac imaging; high resolution small animal imaging; mice; myocardial postischemic inflammation; physiologic processes; rat hearts; rats; small field-of-view gamma camera; static planar pinhole pet-fusion images; Animals; Cameras; Heart; High-resolution imaging; Image resolution; Instruments; Mice; Optical imaging; Photomultipliers; Rats;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2002 IEEE
Print_ISBN
0-7803-7636-6
Type
conf
DOI
10.1109/NSSMIC.2002.1239664
Filename
1239664
Link To Document