DocumentCode :
2198650
Title :
Application of a small field of view gamma camera based on a 5" PSPMT and crystal scintillator array for high resolution small animal cardiac imaging
Author :
Goode, Allen R. ; Glover, David K. ; Watson, Denny D. ; Beller, George A. ; Riou, Laurent M. ; Lima, Ronaldo ; Hatada, Ken ; Ruiz, Mirta ; Kross, Brian ; Majewski, Stan ; Popov, Vladimir ; Smith, Mark F. ; Weisenberger, Andrew G. ; Welch, Benjamin ; Wojci
Author_Institution :
Univ. of Virginia Health Svstem, Charlottesville, VA, USA
Volume :
3
fYear :
2002
fDate :
10-16 Nov. 2002
Firstpage :
1765
Abstract :
We have built a small field-of-view gamma camera based on a 5" diameter Hamamatsu R3292 position sensitive photomultiplier tubes (PSPMT) and Nal(Tl) crystal for high resolution small animal imaging. The instrument was specifically developed for high performance cardiac imaging in rats and mice. Results of measurements in both mouse and rat models will be presented. Dynamic ECG-gated and static planar pinhole pet-fusion images of rat hearts were acquired allowing semi-quantitative and functional interpretation. Additionally, molecular imaging of neutrophil infiltration in a mouse model of myocardial post-ischemic inflammation vi-as performed. We demonstrate the utility of this high resolution instrument for molecular and functional cardiac imaging in small animal models a( heart rates of 250-600 bpm. The superior performance of this new camera will allow the noninvasive monitoring of radiolabeled molecular probes for assessing physiologic processes in the heart as well as other organ systems of small animals.
Keywords :
cardiology; gamma-ray detection; photomultipliers; position sensitive particle detectors; single photon emission computed tomography; solid scintillation detectors; veterinary medicine; Hamamatsu R3292 position sensitive photomultiplier tubes; NaI(Tl) crystal; NaI:Tl; dynamic ECG-gated pinhole pet-fusion images; functional cardiac imaging; high performance cardiac imaging; high resolution small animal imaging; mice; myocardial postischemic inflammation; physiologic processes; rat hearts; rats; small field-of-view gamma camera; static planar pinhole pet-fusion images; Animals; Cameras; Heart; High-resolution imaging; Image resolution; Instruments; Mice; Optical imaging; Photomultipliers; Rats;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2002 IEEE
Print_ISBN :
0-7803-7636-6
Type :
conf
DOI :
10.1109/NSSMIC.2002.1239664
Filename :
1239664
Link To Document :
بازگشت