DocumentCode :
2202566
Title :
Two main factors to the effect of nonlinear characteristics of turbo-generator
Author :
Liang, Meng ; Xinli, Zhang ; Yingli, Luo ; Hao, Liu
Author_Institution :
North China Electr. Power Univ., Beijing
fYear :
2004
fDate :
10-10 June 2004
Firstpage :
1978
Abstract :
By the means of finite element method (FEM), the nonlinear characteristic curves and magnetic field distribution of a 300 MW turbine generator under normal or abnormal operating condition are obtained, it is found that the iron saturation and magnetic field distortion are two main factors which cause the nonlinear phenomenon. When the power angle is given, different exciting currents will result in different magnetic leakage field distribution and as a result affect the rotor iron saturation degree. Thus in order to produce a certain E delta, the required value of resultant current ISigma will vary with the change of saturation status; besides, with a large power angle, the magnetic field distortion will lengthen the air-gap part of the main magnetic path and then influence the value of air-gap voltage Edelta
Keywords :
finite element analysis; iron; magnetic leakage; rotors; turbogenerators; FEM; air-gap voltage; finite element method; magnetic field distortion; magnetic leakage field distribution; nonlinear characteristic; power angle; rotor iron saturation; turbo-generator; Air gaps; Character generation; Iron; Magnetic analysis; Magnetic fields; Nonlinear distortion; Power generation; Power system modeling; Saturation magnetization; Synchronous generators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Engineering Society General Meeting, 2004. IEEE
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-8465-2
Type :
conf
DOI :
10.1109/PES.2004.1373223
Filename :
1373223
Link To Document :
بازگشت