DocumentCode :
2203894
Title :
Detection of Explosives Vapors with a Portable Detector Based on Quartz-Crystal Microbalance
Author :
Parret, F. ; Montméat, P. ; Prené, P.
Author_Institution :
CEA Le Ripault, Monts
fYear :
2007
fDate :
28-31 Oct. 2007
Firstpage :
248
Lastpage :
251
Abstract :
This paper presents the development of a portable gas sensor device prototype able to detect explosives vapors as 2,4 dinitrotoluene (DNT). This detector is based on a single polymer coated quartz crystal microbalance and an appropriate data processing implemented on a microcontroller. Several polymeric materials have been chosen and their sensitivity performances have been evaluated to determinate the most suitable material for DNT detection. This device offers a great sensitivity for DNT exposures (150 Hz/ppm), but this one is also selective towards interfering solvents exposures (< 1 Hz/ppm), independently from temperature and moist conditions.
Keywords :
explosives; gas sensors; microbalances; explosives vapors; portable detector; portable gas sensor device prototype; quartz-crystal microbalance; Crystalline materials; Data processing; Explosives; Gas detectors; Microcontrollers; Performance evaluation; Polymer films; Prototypes; Solvents; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2007 IEEE
Conference_Location :
Atlanta, GA
ISSN :
1930-0395
Print_ISBN :
978-1-4244-1261-7
Electronic_ISBN :
1930-0395
Type :
conf
DOI :
10.1109/ICSENS.2007.4388383