    As a result of recent research work within the Pirelli Cable laboratories to improve the resistance of standard crosslinked polyethylene (XLPE) to water treeing, a specific nonionic surfactant additive has been identified, which significantly increased the water treeing resistance of polyethylene-based insulating material for power cables. Electrical testing on full size cables made to the AEIC Specifications with the newly developed material demonstrated significant effectiveness in retarding water treeing and excellent electrical performance after long term wet aging as compared to a standard and commercially available treeing retardant XLPE
  • Keywords
    XLPE insulation; ageing; insulation testing; power cable insulation; power cable testing; trees (electrical); AEIC Specifications; Pirelli Cable; crosslinked polyethylene; electrical testing; long term wet aging; medium voltage power cables; nonionic surfactant additive; water treeing retardant materials; Additives; Cable insulation; Electric resistance; Laboratories; Medium voltage; Polyethylene; Power cables; Surface resistance; Testing; Trees - insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1998. Conference Record of the 1998 IEEE International Symposium on
  • Conference_Location
    Arlington, VA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-4927-X
  • Type

    conf

  • DOI
    10.1109/ELINSL.1998.694850
  • Filename
    694850