DocumentCode
2205991
Title
An analogue self-calibration technique for high-resolution video-rate pipelined A/D converters
Author
Goes, J. ; Vital, J.C. ; Franca, J.E.
Author_Institution
IST Center for Microsyst., Inst. Superior Tecnico, Lisbon, Portugal
Volume
2
fYear
1995
fDate
13-16 Aug 1995
Firstpage
740
Abstract
An analogue self-calibration technique employing a high-linearity pulse-counting reference DAC for code-by-code correction is proposed for calibrating both the MDAC nonlinearities and the interstage-gain errors in high-resolution video-rate pipelined analogue-to-digital converters. When compared with alternative code-by-code calibration techniques, the proposed solution has the advantage of correcting also the residue-amplification gain of the calibrated stages while using similar additional resources. An example is presented which reveals the effectiveness of such solution
Keywords
analogue-digital conversion; calibration; pipeline processing; video signal processing; analogue self-calibration technique; code-by-code correction; high-resolution; interstage-gain errors; pipelined A/D converters; video-rate ADC; Analog integrated circuits; Analog-digital conversion; CMOS technology; Calibration; Capacitance; Error correction codes; Logic; Pipeline processing; Pulse circuits; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Circuits and Systems, 1995., Proceedings., Proceedings of the 38th Midwest Symposium on
Conference_Location
Rio de Janeiro
Print_ISBN
0-7803-2972-4
Type
conf
DOI
10.1109/MWSCAS.1995.510195
Filename
510195
Link To Document