Title :
Design of the Ross Pairs for Soft X-ray Spectrometer
Author :
Wenyong Miao ; Yongkun Ding ; Kexi Sun ; Dongxian Lai ; Zhenglin Chen ; Hongbin Wang ; Jinxiu Cheng ; Zhijian Zheng ; Hansheng Peng
Author_Institution :
Res. Center of Laser Fusion, China Acad. of Eng. Phys., China
Abstract :
Summary form only given. The measurement of intense, low-energy X-ray pulses has received a significant degree of attention in the last few years because the Z pinch and other plasma devices have a great development. In this paper, the authors introduce a design method of the Ross filter pairs for a soft X-ray spectrometer. The spectrometer consists of 5 channels Ross pairs, 10 X-ray diode (XRD) and some oscilloscopes. This spectrometer covers the energy interval of interest (0.1-1.5keV) without gaps. The Ross pairs´ transmission efficiency and thickness of each pair is calculated by a computer code in order to make the filters have a plain response to the given energy.
Keywords :
X-ray spectrometers; spectrometer accessories; 0.1 to 1.5 keV; Ross filter pairs; Ross pairs; X-ray diode; channels; computer code; energy; intense low-energy X-ray pulses; oscilloscopes; pair thickness; soft X-ray spectrometer; spectrometer; transmission efficiency; Delay effects; Design methodology; Electric variables measurement; Filters; Plasma devices; Plasma measurements; Plasma temperature; Plasma x-ray sources; Pulse measurements; Spectroscopy;
Conference_Titel :
Plasma Science, 2002. ICOPS 2002. IEEE Conference Record - Abstracts. The 29th IEEE International Conference on
Conference_Location :
Banff, Alberta, Canada
Print_ISBN :
0-7803-7407-X
DOI :
10.1109/PLASMA.2002.1030365