Abstract :
This paper describes the results of energy conservation measures in various thermal power plants spread over the country. Energy savings in various major auxiliaries are summarized here with improved performance. Staggering of auxiliary loads, reduction in hydrodynamic resistance of pipes and ducts, adoption of new energy efficient technologies, efficient control techniques, reduction in furnace ingress and monitoring of coal size at mill inlets will lead to substantial amount of energy savings. The energy conservation schemes are economically attractive with a break even period of 1 to 5 years.
Keywords :
electric furnaces; energy conservation; steam power stations; auxiliary power system; coal fired power plant; energy conservation measures; energy efficiency enhancement; energy savings; hydrodynamic resistance; thermal power plants; Boilers; Energy conservation; Fans; Feeds; Fluid flow; Loading; Power generation; auxiliary power; energy conservation; plant load factor;