DocumentCode :
2208816
Title :
Effect of gland quality on the screening effectiveness of cable-connector assemblies
Author :
Deschenes, Patrick ; Bijman, Rob ; Leferink, Frank
Author_Institution :
Thales Netherlands, Hengelo, The Netherlands
fYear :
2015
fDate :
16-22 Aug. 2015
Firstpage :
62
Lastpage :
67
Abstract :
An extensive number of standards provide various transfer impedance requirements and test methods for individual cables, but just a few are related to connectors. Only two standards describe how to test cable-gland-connector-receptacle assemblies. The cable-gland-connector-receptacle assembly has significant effects on the total considered impedance chain. In general the supplier for cable, gland and connector is different. For the introduction of commercial off the shelf connectors tests were performed on connectors and cable-connector sets, and inconsistent results were observed, showing extremely high transfer impedance, thus poor screening effectiveness. It is shown that the transfer impedance of such glands is greatly dependent on its shape, and how glands are mounted.
Keywords :
Assembly; Cable shielding; Connectors; Glands; Impedance; Power cables; Standards; Transfer impedance; cable; connector; gland; screening attenuation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2015 IEEE International Symposium on
Conference_Location :
Dresden, Germany
Print_ISBN :
978-1-4799-6615-8
Type :
conf
DOI :
10.1109/ISEMC.2015.7256133
Filename :
7256133
Link To Document :
بازگشت