DocumentCode
2210921
Title
SUOMI NPP VIIRS emissive band radiance calibration and analysis
Author
Liu, Quanhua ; Cao, Changyong ; Weng, Fuzhong
Author_Institution
Joint Center for Satellite Data Assimilation, Univ. of Maryland, Camp Springs, MD, USA
fYear
2012
fDate
22-27 July 2012
Firstpage
1053
Lastpage
1056
Abstract
VIIRS thermal emissive bands (TEB) have been analyzed. The analysis results indicate the VIIRS TEB is stable and exceeds the specification. Comparisons between the VIIRS and other sensors such as AVHRR, MODIS and CrIS demonstrated that VIIRS TEB agrees well with those sensors. Using Community Radiative Transfer Model (CRTM), developed at U.S. Joint Center for Satellite Data Assimilation (JCSDA), we found that M12 band image striping at day time over a uniform ocean was caused by the difference of sensor azimuthal angles among detectors.
Keywords
calibration; geophysical equipment; geophysical techniques; Community Radiative Transfer Model; M12 band image striping; SUOMI NPP VIIRS emissive band radiance analysis; SUOMI NPP VIIRS emissive band radiance calibration; US Joint Center for Satellite Data Assimilation; VIIRS thermal emissive bands; sensor azimuthal angles; uniform ocean; Calibration; Detectors; MODIS; Satellites; Temperature measurement; Calibration; Thermal Emissive Band; VIIRS;
fLanguage
English
Publisher
ieee
Conference_Titel
Geoscience and Remote Sensing Symposium (IGARSS), 2012 IEEE International
Conference_Location
Munich
ISSN
2153-6996
Print_ISBN
978-1-4673-1160-1
Electronic_ISBN
2153-6996
Type
conf
DOI
10.1109/IGARSS.2012.6351370
Filename
6351370
Link To Document