• DocumentCode
    2211887
  • Title

    The design of an animal PET: flexible geometry for achieving optimal spatial resolution or high sensitivity

  • Author

    Weber, S. ; Terstegge, A. ; Halling, H. ; Herzog, H. ; Reinartz, R. ; Reinhart, P. ; Rongen, F. ; Müller-Gärtner, H.W.

  • Author_Institution
    Inst. fur Med., Forschungszentrum Julich GmbH, Germany
  • Volume
    2
  • fYear
    1995
  • fDate
    21-28 Oct 1995
  • Firstpage
    1002
  • Abstract
    A positron emission tomograph (PET) for small animals, e.g. rabbits or rats, is under development at the KFA Juelich as a cooperative effort between the Institute of Medicine which includes a PET center, the Central Laboratory for Electronics and the Institute for Thin Film and Ion Technology (ISI). The first version of the scanner uses arrays of small individual Yttrium Aluminium Perovskit (YAP) scintillator crystals coupled to position sensitive photomultiplier tubes. Special hardware has been built for coincidence detection, position detection and real time data acquisition, which is performed by a PC. The single event data are transfered to workstations, where the radioactivity distribution is reconstructed. The fundamental design features have extensively been simulated. Preliminary studies were carried out by using single NaI:Tl crystals coupled to position sensitive photomultiplier tubes. For the reconstruction of the simulated source configurations and measured data a 3D EM-algorithm has been implemented. The main advantage of the animal PET scanner is its high flexibility, allowing the realization of various detector system configurations. The system is capable of either providing good spatial resolution or high sensitivity for dynamic studies of pharmacokinetics. The reconstruction software is flexible and matches the different choices
  • Keywords
    biological techniques; geometry; image reconstruction; image resolution; positron emission tomography; 3D EM-algorithm; Central Laboratory for Electronics; Institute for Thin Film and Ion Technology; Institute of Medicine; KFA Juelich; NaI:Tl; YAP; YAlO3; animal PET design; detector system configurations; flexible geometry; high sensitivity; optimal spatial resolution; position sensitive photomultiplier tubes; rabbits; radioactivity distribution; rats; reconstruction software; simulated source configurations reconstruction; small individual Yttrium Aluminium Perovskit scintillator crystals; Animals; Crystals; Event detection; Geometry; Laboratories; Photomultipliers; Positron emission tomography; Rabbits; Radioactive decay; Rats;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-3180-X
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1995.510435
  • Filename
    510435