DocumentCode :
2212398
Title :
Uncertainty evaluation of conducted emission measurements by means of conformal mapping
Author :
Audone, Bruno ; Finizio, Alberto F. ; Colombo, Roberto
Author_Institution :
EMC, Torino, Italy
fYear :
2015
fDate :
16-22 Aug. 2015
Firstpage :
924
Lastpage :
929
Abstract :
Conformal mapping is used to investigate the uncertainties of conducted emission tests on power supply lines, taking into account the requirements of test components specified by most EMC standards. Unfortunately, there is no clear common approach in the definition of the coupling devices located between the EUT (equipment under test) and the EMI receiver. Therefore, test reproducibility may be affected and an additional contribution may be added to the overall uncertainty of the test.
Keywords :
Couplings; Electromagnetic interference; Measurement uncertainty; AMN; CDN; CDNE; conducted emissions; conformal mapping; extra element theorem; independent method of measurement of radiated disturbances; uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2015 IEEE International Symposium on
Conference_Location :
Dresden, Germany
Print_ISBN :
978-1-4799-6615-8
Type :
conf
DOI :
10.1109/ISEMC.2015.7256289
Filename :
7256289
Link To Document :
بازگشت