• DocumentCode
    2212560
  • Title

    Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: Myocardial perfusion assessment

  • Author

    Blankespoor, S.C. ; Wu, X. ; Kalki, K. ; Brown, J.K. ; Cann, C.E. ; Hasegawa, B.H.

  • Author_Institution
    California Univ., San Francisco, CA, USA
  • Volume
    2
  • fYear
    1995
  • fDate
    21-28 Oct 1995
  • Firstpage
    1126
  • Abstract
    We present experimental results for attenuation correction of emission tomography through use of an attenuation map derived from X-ray CT data. Both the X-ray and gamma-ray data were obtained on a prototype emission-transmission imaging system (“X-SPECT”) which incorporates a third-generation X-ray CT scanner and a single-headed SPECT scanner. The two commercial imaging devices are juxtaposed such that the CT table can move the patient directly into the SPECT scanner after the X-ray scan. This enables systematic registration of SPECT and X-ray CT images. To calibrate attenuation map creation, a set of CT scans for a specific phantom geometry and X-ray technique were acquired, with varying attenuating materials in each scan. A piecewise linear fit was applied to the CT numbers and known attenuation coefficients at 140 keV, and the result is used to create attenuation maps at 140 keV from given CT images. This technique has been applied to small pigs in myocardial perfusion studies. Correcting for attenuation increased the image-derived myocardial radionuclide concentration values from 16% of the values observed for excised myocardium to 35% (ignoring background). Adding an additional correction for partial volume effects increases the image-derived value to 93% of the expected value (ignoring background). Precision, however, remains limited
  • Keywords
    cardiology; computerised tomography; image reconstruction; image registration; medical image processing; muscle; single photon emission computed tomography; 140 keV; SPECT; X-ray CT; attenuation correction; attenuation map; emission tomography; emission-transmission CT system; gamma-ray data; image-derived myocardial radionuclide concentration values; myocardial perfusion assessment; partial volume effects; piecewise linear fit; single-headed SPECT scanner; small pigs; specific phantom geometry; third-generation X-ray CT scanner; Attenuation; Cameras; Computed tomography; Electromagnetic scattering; Myocardium; Optical imaging; Particle scattering; Single photon emission computed tomography; X-ray imaging; X-ray scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-3180-X
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1995.510461
  • Filename
    510461