DocumentCode
2213487
Title
Power-Factor Fluctuation of Directly Water-Cooled Generator-Bar after Water-Penetration inside the Groundwall Insulation
Author
Naghashan, M.R. ; Farrokhi, M.
Author_Institution
Power & Water Univ. of Technol., Tehran
fYear
2008
fDate
9-12 June 2008
Firstpage
273
Lastpage
275
Abstract
A directly water-cooled generator-bar with laboratory tests is presented in this paper. A leak point is made inside the groundwall insulation of the bar. The cooling water migrates along the generator bar through insulation delamination and interstices between copper strands. The speed of water flow inside the insulation is measured during the test period. Capacitance and power-factor mapping tests are carried out along the generator-bar length. The results show that the capacitance and dissipation factor are fluctuated reversely over a period of time. Dissipation factor variation of the generator-bar is higher than the capacitance variation.
Keywords
bars; capacitance; cooling; electric generators; insulation testing; machine insulation; machine testing; power factor; velocity measurement; capacitance tests; direct water-cooled generator-bar; dissipation factor variation; flow speed measurement; groundwall insulation test; insulation delamination; power-factor fluctuation; power-factor mapping tests; water-penetration; Capacitance; Cooling; Copper; Delamination; Fluctuations; Fluid flow measurement; Insulation; Laboratories; Power generation; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, 2008. ISEI 2008. Conference Record of the 2008 IEEE International Symposium on
Conference_Location
Vancouver, BC
ISSN
1089-084X
Print_ISBN
978-1-4244-2091-9
Electronic_ISBN
1089-084X
Type
conf
DOI
10.1109/ELINSL.2008.4570327
Filename
4570327
Link To Document