• DocumentCode
    2217341
  • Title

    Properties of open strip lines for EMC measurements

  • Author

    Bittinger, Wolfgang

  • fYear
    1993
  • fDate
    9-13 Aug 1993
  • Firstpage
    120
  • Lastpage
    125
  • Abstract
    The operation of strip lines for susceptibility testing inside a shielded enclosure can cause large errors because of room resonances. The repercussion of these resonances upon the field inside the strip line is investigated. The quality of automatic field strength control at a reference point inside the line is checked for various arrangements of small ferrite and pyramid absorbers close to the waveguide structure. Satisfactory performance is obtained up to 400 MHz with a simple solution at low cost
  • Keywords
    Costs; Electromagnetic compatibility; Electronic equipment testing; Ferrites; Frequency; Geometry; Probes; Resonance; Signal generators; Strips;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1993. Symposium Record., 1993 IEEE International Symposium on
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-1304-6
  • Type

    conf

  • DOI
    10.1109/ISEMC.1993.473766
  • Filename
    473766