• DocumentCode
    2218427
  • Title

    Measurement system for electrical impedance and EGG

  • Author

    Li, ZhangYong ; He, Zhonghua ; Wang, Wei ; Ren, Chaoshi

  • Author_Institution
    Dept. of Biomed. Eng., ChongQing Univ. of Posts & Telecommun., Chongqing
  • fYear
    2008
  • fDate
    30-31 May 2008
  • Firstpage
    495
  • Lastpage
    498
  • Abstract
    This paper describes a measurement system measuring electrical impedance signal and synchronous electrogastrogram (EGG). Electrical impedance signal is measured with the conventional tetrapolar method. Two outer electrodes insert 2 mA, 50kHz constant current on epigastric surface of body, and voltage is measured using inner two electrodes. In this paper, ADuC834 was selected to collect the low-frequency gastric impedance signal and the series control SPCOMM was employed to sample the signal from the ADuC834. Both signal collected from body surface are off-line decomposed by multi-resolution analysis. Wavelet transform is addressed to separate the electrical impedance signal from respiratory artifacts and blood flowing artifacts. We did some experiment to test the quality of this measurement system in clinical conditions and research the gastric motility and gastric emptying in time domain and frequency domain. According to preliminary experiment, the system has good performance in measurement precision. The result showed that ADuC834 is suitable for extracting the low frequency gastric impedance signal and wavelet transform have good performance to get rid of the interference.
  • Keywords
    bioelectric phenomena; biomedical electrodes; biomedical measurement; haemodynamics; medical signal processing; pneumodynamics; wavelet transforms; ADuC834 signal; EGG; blood flowing artifacts; electrical impedance; electrodes; epigastric surface; gastric emptying; gastric impedance signal; gastric motility; measurement precision; measurement system; multiresolution analysis; respiratory artifacts; synchronous electrogastrogram; tetrapolar method; wavelet transform; Blood; Current measurement; Electric variables measurement; Electrodes; Impedance measurement; Signal analysis; Surface impedance; System testing; Voltage measurement; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Technology and Applications in Biomedicine, 2008. ITAB 2008. International Conference on
  • Conference_Location
    Shenzhen
  • Print_ISBN
    978-1-4244-2254-8
  • Electronic_ISBN
    978-1-4244-2255-5
  • Type

    conf

  • DOI
    10.1109/ITAB.2008.4570598
  • Filename
    4570598