• DocumentCode
    2222088
  • Title

    A systematic study of EMI reduction by physical converter layout and suppressive circuits

  • Author

    Sinclair, A.J. ; Ferreira, J.A. ; van Wyk, J.D.

  • Author_Institution
    Energy Lab., Rand Afrikaans Univ., Johannesburg, South Africa
  • fYear
    1993
  • fDate
    15-19 Nov 1993
  • Firstpage
    1059
  • Abstract
    A full-bridge PWM power converter was investigated for conducted EMI, minor modifications to the mechanical and electrical construction were made and their effects on conducted EMI were measured. This includes snubber circuits, different self-capacitances of inductors, grounding of heat sinks and circuit parasitic inductances. The authors describe how the appropriate use of snubbers and due attention to parasitic elements can improve the conducted EMI of a power converter, obviating the need for costly and bulky EMI filters
  • Keywords
    bridge circuits; circuit layout; earthing; electromagnetic interference; heat sinks; overvoltage protection; power convertors; power inductors; pulse width modulation; circuit parasitic inductances; conducted EMI; full-bridge PWM power converter; grounding; heat sinks; inductors; physical layout; self-capacitances; snubber circuits; suppressive circuits; Circuits; Electric variables measurement; Electromagnetic interference; Grounding; Inductors; Mechanical variables measurement; Power measurement; Pulse width modulation; Pulse width modulation converters; Snubbers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, Control, and Instrumentation, 1993. Proceedings of the IECON '93., International Conference on
  • Conference_Location
    Maui, HI
  • Print_ISBN
    0-7803-0891-3
  • Type

    conf

  • DOI
    10.1109/IECON.1993.339128
  • Filename
    339128