DocumentCode
2239973
Title
Induction motor residual voltage
Author
Akiyama, Yuji
Author_Institution
Kanagawa Inst. of Technol., Japan
fYear
1990
fDate
7-12 Oct. 1990
Firstpage
24
Abstract
The residual voltage in an induction motor under an interrupted power supply condition is considered. The electromagnetic shock at the end of the motor coil due to the excessive surge current and the mechanical impact due to the greater transient torque are investigated. The case when many induction motors are connected to a common bus is studied. Development of the analytical model and a method of decreasing rapidly the residual voltage are described. Simulation and experimental results are compared and show fair agreement.<>
Keywords
induction motors; electromagnetic shock; excessive surge current; induction motor; interrupted power supply; mechanical impact; residual voltage; transient torque; Analytical models; Computational modeling; Differential equations; Equivalent circuits; Frequency; Induction motors; Power supplies; Rotors; Transformers; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 1990., Conference Record of the 1990 IEEE
Conference_Location
Seattle, WA, USA
Print_ISBN
0-87942-553-9
Type
conf
DOI
10.1109/IAS.1990.152160