• DocumentCode
    2239973
  • Title

    Induction motor residual voltage

  • Author

    Akiyama, Yuji

  • Author_Institution
    Kanagawa Inst. of Technol., Japan
  • fYear
    1990
  • fDate
    7-12 Oct. 1990
  • Firstpage
    24
  • Abstract
    The residual voltage in an induction motor under an interrupted power supply condition is considered. The electromagnetic shock at the end of the motor coil due to the excessive surge current and the mechanical impact due to the greater transient torque are investigated. The case when many induction motors are connected to a common bus is studied. Development of the analytical model and a method of decreasing rapidly the residual voltage are described. Simulation and experimental results are compared and show fair agreement.<>
  • Keywords
    induction motors; electromagnetic shock; excessive surge current; induction motor; interrupted power supply; mechanical impact; residual voltage; transient torque; Analytical models; Computational modeling; Differential equations; Equivalent circuits; Frequency; Induction motors; Power supplies; Rotors; Transformers; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 1990., Conference Record of the 1990 IEEE
  • Conference_Location
    Seattle, WA, USA
  • Print_ISBN
    0-87942-553-9
  • Type

    conf

  • DOI
    10.1109/IAS.1990.152160
  • Filename
    152160