Title :
Determination of complex residual error parameters of a calibrated vector network analyzer
Author :
Wubbeler, Gerd ; Elster, Clemens ; Reichel, Thomas ; Judaschke, Rolf
Author_Institution :
Phys.-Tech. Bundesanstalt, Berlin, Germany
Abstract :
A novel technique for the determination of the residual directivity and the residual source match of a calibrated one-port vector network analyzer is investigated. The method corresponds to the ¿ripple extraction¿ schemes and is based on a single reflection measurement employing a high precision airline terminated by a short. The complex-valued residual system errors are not directly measured, but will be extracted over the entire measured frequency range by a sophisticated data analyzing scheme utilizing, among other things, bandpass filtering and linear prediction. By modeling the utilized short, also the residual reflection tracking can be estimated. Thus, in comparison with a standard SOL calibration (performed with sliding load), a VNA accuracy enhancement can be achieved by second-order error correction.
Keywords :
calibration; measurement uncertainty; network analysers; bandpass filtering; calibrated vector network analyzer; complex residual error parameters; linear prediction; one-port vector network analyzer; residual directivity; residual source match; second-order error correction; single reflection measurement; Band pass filters; Calibration; Data analysis; Data mining; Error correction; Filtering; Frequency measurement; Nonlinear filters; Reflection; Termination of employment; linear prediction; residual error parameter; vector network analyzer calibration;
Conference_Titel :
ARFTG Conference, 2007 69th
Conference_Location :
Honolulu, HI
Print_ISBN :
978-0-7803-9762-0
Electronic_ISBN :
978-0-7803-9763-7
DOI :
10.1109/ARFTG.2007.5456312