DocumentCode :
2247771
Title :
The failure of coaxial TEM cells ASTM standards methods in H.F. range
Author :
Badic, Mihai ; Marinescu, Mihai-Jo
Author_Institution :
HV/EMC Lab., ICPE, Bucharest, Romania
Volume :
1
fYear :
2002
fDate :
19-23 Aug. 2002
Firstpage :
29
Abstract :
The paper deals with one of the most used and reliable ways to characterize the shielding capability of materials, based on the Schelkunoff isomorphism. This method uses the physical-mathematical equivalence of equations describing SEdB in the case of infinite plane shield, respectively in the case of material sample introduced in the measuring coaxial TEM cell (IAdB), and it resulted into the ASTM standards ES7-83 and D4935-89. The paper shows that these standards (and Schelkunoff isomorphism) are not valid for electrically thick samples; there is no identity between shielding effectiveness and insertion attenuation/insertion loss in H.F. range.
Keywords :
TEM cells; electromagnetic shielding; failure analysis; measurement standards; reliability; telecommunication standards; ASTM standards methods; D4935-89; ES7-83; HF range; Schelkunoff isomorphism; coaxial TEM cells failure; infinite plane shield; shielding capability characterisation; Area measurement; Coaxial components; Conducting materials; Electromagnetic measurements; Equations; Extraterrestrial measurements; Frequency; Impedance measurement; Measurement standards; TEM cells;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2002. EMC 2002. IEEE International Symposium on
Conference_Location :
Minneapolis, MN, USA
Print_ISBN :
0-7803-7264-6
Type :
conf
DOI :
10.1109/ISEMC.2002.1032442
Filename :
1032442
Link To Document :
بازگشت