DocumentCode
2252851
Title
Early detection of steam leaks in nuclear plant
Author
Sutton, R. ; Parkins, M.J.
Author_Institution
R. Naval Eng. Coll., Greenwich, UK
fYear
1991
fDate
25-28 Mar 1991
Firstpage
75
Abstract
As emergency scenarios arise it is essential that the operator of a nuclear power station is not overloaded with irrelevant information. Thus the need for informative monitoring systems as an integral part of the nuclear plant are necessary to ensure the workload of the operator is not unduly increased, especially during high stress situations. A fuzzy safety monitoring system for the early detection of steam links in Royal Navy nuclear steam raising plant is described. The system is based on an interpretation into a set of fuzzy rules of the internal representation of a supervisor employed in monitoring given plant parameters
Keywords
computerised monitoring; fission reactor safety; fuzzy logic; nuclear power stations; Royal Navy nuclear steam raising plant; emergency scenarios; fuzzy safety monitoring system; informative monitoring systems; nuclear power station; steam leak detection;
fLanguage
English
Publisher
iet
Conference_Titel
Control 1991. Control '91., International Conference on
Conference_Location
Edinburgh
Print_ISBN
0-85296-509-5