• DocumentCode
    2252871
  • Title

    Model-based leakage detection in a pulverized coal injection vessel

  • Author

    Johansson, Andreas ; Medvedev, Alexander

  • Author_Institution
    Control Eng. Group, Lulea Univ. of Technol., Sweden
  • Volume
    3
  • fYear
    1998
  • fDate
    21-26 Jun 1998
  • Firstpage
    1742
  • Abstract
    A method for detecting and isolating incipient leakages in the valves of a pulverized coal injection vessel for a blast furnace process is presented. Nonlinear physical gray-box models of the plant are developed. Values of the unknown parameters are estimated by identification. Observers are constructed for these models and the residuals are used in a generalized likelihood ratio test. The method is successfully tested with real leakages intentionally introduced in the plant
  • Keywords
    fault diagnosis; furnaces; leak detection; observers; parameter estimation; pulverised fuels; statistical analysis; valves; blast furnace process; fault detection and isolation; generalized likelihood ratio test; model-based leakage detection; nonlinear physical gray-box models; pulverized coal injection vessel; residuals; valves; Blast furnaces; Electrical fault detection; Fault detection; Isolation technology; Leak detection; Nitrogen; Observers; Powders; Testing; Valves;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 1998. Proceedings of the 1998
  • Conference_Location
    Philadelphia, PA
  • ISSN
    0743-1619
  • Print_ISBN
    0-7803-4530-4
  • Type

    conf

  • DOI
    10.1109/ACC.1998.707305
  • Filename
    707305