Title :
Transmission Loss And Radiated Electric Field Characteristics of Transmission Medium for Ubiquitous Network
Author :
Higuma, Toshiyasu ; Kushiro, Noriyuki ; Nakata, Masanori ; Watanabe, Yosuke ; Tokuda, Masamitsu
Author_Institution :
Lab. of Living Environ. Syst., Mitsubishi Electr. Corp.
Abstract :
Transmission loss and radiated electric field characteristics of the pipe-based transmission line as new transmission medium are calculated by using the method of moment, and it is clear that the calculated values almost agreed with measured values. In addition, it is confirmed that the pipe based transmission system can obtain dynamic range of about 56 dB and realize secure transmission, even if the radiated electric field from the pipe-based transmission line comply with the limit of the information technology equipment specified by VCCI.
Keywords :
carrier transmission on power lines; method of moments; air conditioner; method of moment; pipe-based transmission line; radiated electric field characteristics; refrigerant pipes; transmission loss; transmission medium; ubiquitous network; Loss measurement; Mediation; Moment methods; Power line communications; Power transmission lines; Propagation losses; Refrigerants; Transmission line measurements; Transmission line theory; Wireless communication;
Conference_Titel :
Consumer Electronics, 2007. ICCE 2007. Digest of Technical Papers. International Conference on
Conference_Location :
Las Vegas, NV
Print_ISBN :
1-4244-0763-X
Electronic_ISBN :
1-4244-0763-X
DOI :
10.1109/ICCE.2007.341505