• DocumentCode
    2256891
  • Title

    Biological cell assays on an electrokinetic microchip

  • Author

    Andersson, P.E. ; Li, P.C.H. ; Smith, R. ; Szarka, R.J. ; Harrison, D.J.

  • Author_Institution
    Dept. of Chem., Alberta Univ., Edmonton, Alta., Canada
  • Volume
    2
  • fYear
    1997
  • fDate
    16-19 Jun 1997
  • Firstpage
    1311
  • Abstract
    A technique for single cell assay of non adherent cells is demonstrated by using microfabricated flow manifolds and video fluorescence microscopy. The kinetic cellular event of calcium flux release was determined in human lymphocytes. Transport, incubation and reactions on the microchip was accomplished using either electroosmotic or hydrodynamic pumping
  • Keywords
    bioelectric phenomena; biomembrane transport; biosensors; blood; calcium; electrokinetic effects; fluorescence; optical microscopy; Ca; biological cell assays; calcium flux release; electrokinetic microchip; electroosmotic pumping; human lymphocytes; hydrodynamic pumping; incubation; kinetic cellular event; microfabricated flow manifolds; nonadherent cells; single cell assay technique; video fluorescence microscopy; Biological cells; Calcium; Cells (biology); Electrokinetics; Fluorescence; Fungi; Humans; Kinetic theory; Microscopy; Red blood cells;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid State Sensors and Actuators, 1997. TRANSDUCERS '97 Chicago., 1997 International Conference on
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    0-7803-3829-4
  • Type

    conf

  • DOI
    10.1109/SENSOR.1997.635477
  • Filename
    635477