• DocumentCode
    2257758
  • Title

    Remote blood pressure monitoring using a pulse diagnostic system in TCM and Android-based Tablet PC

  • Author

    Shin, K.Y. ; Kim, T.K. ; Song, J.S. ; Jin, S.O.

  • Author_Institution
    Korea Electrotechnol. Res. Inst., Ansan, South Korea
  • fYear
    2012
  • fDate
    5-7 Jan. 2012
  • Firstpage
    647
  • Lastpage
    650
  • Abstract
    It has become popular to combine both Traditional Chinese Medicine (TCM) and Western medicine for the diagnosis and treatment of patients since such an approach can be noninvasive and allows for the individualized diagnosis and treatment. One method of diagnosis used in Chinese medicine is pulse taking, which involves the same fundamental principals measuring blood pressure by tonometry in Western medicine. The accuracy of blood pressure measurements using tonometry is lower than the accuracy achieved using an electric monometer. Therefore in this study, a multiple regression equation was developed to improve the accuracy of blood pressure measurements using a pulse diagnostic apparatus. When this equation was used, the mean difference of 3.3mmHg and standard deviation of 2.4mmHg during the contraction phase and the mean difference of 3.6mgHg and standard deviation of 2.6mmHg during the relaxation phase were calculated. This is statistically significant and satisfies the criteria of the mean difference of 5mmHg and standard deviation of 8.0mmHg stated in ANSI/AAMI SP10. In addition, we develop an Android-based telemedicine system using a Tablet PC to measure blood pressure.
  • Keywords
    biomedical telemetry; blood pressure measurement; operating systems (computers); patient diagnosis; patient monitoring; patient treatment; regression analysis; telemedicine; ANSI/AAMI SPIO; Android-based tablet PC; Android-based telemedicine system; TCM; Western medicine; blood pressure measurement; contraction phase; multiple regression equation; patient diagnosis; patient treatment; pulse diagnostic apparatus; relaxation phase; remote blood pressure monitoring; tonometry; traditional Chinese medicine; Electric variables measurement; Equations; Medical diagnostic imaging; Phase measurement; Pressure measurement; Pulse measurements; Telemedicine;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical and Health Informatics (BHI), 2012 IEEE-EMBS International Conference on
  • Conference_Location
    Hong Kong
  • Print_ISBN
    978-1-4577-2176-2
  • Electronic_ISBN
    978-1-4577-2175-5
  • Type

    conf

  • DOI
    10.1109/BHI.2012.6211666
  • Filename
    6211666