DocumentCode :
2258426
Title :
Long-term aged performances of stator insulation for wind turbine generator under repeat pulse voltage
Author :
Liu Xuezhong ; Zhao Xiang ; Wang Ying ; Chen Xiaocong ; Li Dandan
Author_Institution :
State Key Lab. of Electr. Insulation & Power Equip., Xi´an Jiaotong Univ., Xi´an, China
fYear :
2011
fDate :
6-10 Sept. 2011
Firstpage :
105
Lastpage :
108
Abstract :
The power inverter between the wind turbine generator and electrical grid is commonly used for adjusting or converting the generator frequency and voltage to the grid. The stator or rotor insulation of generator will endure the step repeat pulse voltages. It has become important to evaluate the stator insulation of wind turbine generator under repeat pulse voltages. Firstly, the lab test setup with the repeat-pulsed voltage up to 10kV and frequency up to 20kHz was established, and the full sized specimens of stator insulation for megawatt direct-driven permanent magnet generator were prepared in this paper. Under the different applied voltage, from 4kV to 6.5kV, the electrical ageing or voltage-endurance testing of specimens at a constant temperature were carried out. The ageing duration was from 100hrs to 5000 hrs. During the ageing process, the ageing characteristic parameters of stator specimen were measured periodically, which included the dissipation factor, capacitance, insulation resistance, partial discharge inception voltage and corona discharge inception voltage. The relationships between the ageing characteristic parameters and ageing duration have been obtained, and the residual breakdown voltage of specimen was taken also. Some of aged specimens, if failed, were examined by means of dissection in the area around the insulation puncture in order to identify the failure location and its cause. Some of un-failed specimens were also dissected for the further analysis like as Fourier transform infrared spectroscopy and microscopy.
Keywords :
Fourier transform spectroscopy; ageing; capacitance; corona; fault location; infrared spectroscopy; insulation testing; invertors; partial discharges; permanent magnet generators; power grids; rotors; stators; turbogenerators; wind power plants; wind turbines; Fourier transform infrared spectroscopy; ageing characteristic parameter; capacitance; corona discharge inception voltage; dissipation factor; electrical ageing process; electrical grid; failure location; frequency 20 kHz; insulation puncture; insulation resistance; lab test setup; megawatt direct driven permanent magnet generator; microscopy; partial discharge inception voltage; power inverter; repeat pulse voltage; residual breakdown voltage; rotor insulation; stator insulation; stator specimen; step repeat pulse voltage; time 100 hr to 5000 hr; unfailed specimen; voltage 10 kV; voltage 4 kV to 6.5 kV; voltage endurance testing; wind turbine generator; Aging; Breakdown voltage; Flashover; Stators; Voltage measurement; Wind turbines; electric ageing; megawatt; repeat pulse; stator insulation; wind turbine generator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulating Materials (ISEIM), Proceedings of 2011 International Conference on
Conference_Location :
Kyoto
Print_ISBN :
978-4-88686-074-3
Type :
conf
DOI :
10.1109/ISEIM.2011.6826333
Filename :
6826333