DocumentCode
2260006
Title
Wearable patch for the electrical, durometry and optical skin measurements in tuberculin skin test
Author
Chan, Wai Chun ; Li, Lin Kai ; Yung, Pun To
Author_Institution
Dept. of Electron. Eng., Chinese Univ. of Hong Kong, Shatin, China
fYear
2012
fDate
5-7 Jan. 2012
Firstpage
1001
Lastpage
1004
Abstract
Early diagnosis and prompt treatment of latent tuberculosis infection is important to reduce mortality and morbidity especially among patents with immunocompromised conditions. The tuberculin skin test is a routine screening test for latent tuberculosis based on intradermal immune response sensitization. Results depend on the induration size and risk factors of subject. This test, however, suffers from uncertainty and non-specificity due to ambiguous cutoff value and intra-observer variations. We propose to develop a bandage-type flexible patch to monitor skin impedance, temperature, tissue oxygen saturation, and induration diameter after the tuberculin administration. The multi polymeric patch will consist of highly fibrillated microstructured plastic pillars to mimic the microscopic setae hair at the bottom of gecko feet, allowing dry operation and minimal motion artifact. This flexible device is to be adhered to the injection site recording relevant physiological changes manifested as a result of the immune response towards the injected tuberculin in order to aid the disease assignment. The proposed device not only provides an objective measurement for the tuberculin skin test, but also supplies non-invasive electrodermal readings to supplement the diagnosis of latent tuberculosis infection and epidemiological studies.
Keywords
bioelectric phenomena; diseases; patient diagnosis; skin; temperature measurement; ambiguous cutoff value; bandage type flexible patch; durometry measurements; early diagnosis; electrical measurements; fibrillated microstructured plastic pillars; gecko feet; immunocompromised condition; induration diameter; induration size; intradermal immune response sensitization; intraobserver variation; latent tuberculosis infection; morbidity; mortality; multipolymeric patch; nonspecificity; optical skin measurements; prompt treatment; risk factor; setae hair; skin impedance; skin temperature; tissue oxygen saturation; tuberculin skin test; uncertainty; wearable patch; Immune system; Light emitting diodes; Photodiodes; Size measurement; Skin; Thermal sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical and Health Informatics (BHI), 2012 IEEE-EMBS International Conference on
Conference_Location
Hong Kong
Print_ISBN
978-1-4577-2176-2
Electronic_ISBN
978-1-4577-2175-5
Type
conf
DOI
10.1109/BHI.2012.6211758
Filename
6211758
Link To Document