DocumentCode
2266462
Title
A low-power time interval measurement chip with sub-nanosecond resolution
Author
Raisanen-Ruotsalainen, E. ; Rahkonen, Timo ; Kostamovaara, Juha
Author_Institution
Dept. of Electr. Eng., Oulu Univ., Finland
fYear
1993
fDate
16-18 Aug 1993
Firstpage
1244
Abstract
An integrated time measurement unit for use in portable, low power laser rangefinding devices is described. It is implemented with 1.2 μm CMOS technology and has a measurement range of 10 us and an accuracy of ±0.2 ns over the temperature range 0...60°C and supply voltage range 4.5...5.5 V. Single shot time measurement resolution is ±0.9 ns. Nominal current consumption is 3 mA
Keywords
CMOS integrated circuits; laser ranging; portable instruments; time measurement; 0 to 60 C; 0.2 ns; 0.9 ns; 1.2 micron; 10 mus; 3 mA; 4.5 to 5.5 V; CMOS technology; current consumption; integrated time measurement unit; low-power time interval measurement chip; portable laser rangefinding devices; single shot time measurement resolution; sub-nanosecond resolution; CMOS technology; Clocks; Energy consumption; Frequency; Laser radar; Optical pulses; Power measurement; Pulse measurements; Semiconductor device measurement; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Circuits and Systems, 1993., Proceedings of the 36th Midwest Symposium on
Conference_Location
Detroit, MI
Print_ISBN
0-7803-1760-2
Type
conf
DOI
10.1109/MWSCAS.1993.343322
Filename
343322