DocumentCode :
2270505
Title :
Mixed voltage /current mode control of PWM synchronous buck converter
Author :
Chang, Chin
Author_Institution :
Semtech Corp., Camarillo, CA, USA
Volume :
3
fYear :
2004
fDate :
14-16 Aug. 2004
Firstpage :
1136
Abstract :
In this paper, we propose a mixed voltage/current mode control method of synchronous buck converter. Such mixed mode control lies between the traditional voltage mode and current mode control, but has the advantages of better noise immunity than current mode, better load transient response than voltage mode. While it is possible to design an optimal controller for synchronous buck converter under mixed mode operation, an example is provided to show that the traditional type III compensator is sufficient to stabilize the synchronous buck converter under all the three operating modes with different dynamic response performance.
Keywords :
DC-DC power convertors; PWM power convertors; electric current control; optimal control; transient response; voltage control; PWM synchronous buck converter; compensator; current mode control; dynamic response performance; load transient response; mixed mode control; noise immunity; optimal controller; pulse width modulation; voltage mode control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference, 2004. IPEMC 2004. The 4th International
Conference_Location :
Xi´an
Print_ISBN :
7-5605-1869-9
Type :
conf
Filename :
1376898
Link To Document :
بازگشت