DocumentCode
2271131
Title
Normal force characteristics analysis of single-sided linear induction motor
Author
Huaiji, Lu ; Ying, Zhang ; Yumei, Du
Author_Institution
Sch. of Chinese Acad. of Sci., China
fYear
2011
fDate
20-23 Aug. 2011
Firstpage
1
Lastpage
6
Abstract
The normal force characteristics of single-sided linear induction motor is analyzed using multilayer theory and finite element method (FEM). It is found that the magnetic permeability of back iron affects the analysis results obviously. In this article the equivalent magnetic energy method is used to correct the permeability of back iron in multi-layer approach. As the simulated object, the normal force characteristics of motor A is calculated by multi-layer approach and FEM and compared. On an experiment platform (arc rotating motor), the normal force characteristics obtained by multilayer approach and FEM are verified by experiments.
Keywords
finite element analysis; linear induction motors; magnetic permeability; FEM; arc rotating motor; back iron; equivalent magnetic energy method; finite element method; magnetic permeability; multilayer approach; multilayer theory; normal force characteristics analysis; single-sided linear induction motor; Electromagnetic fields; Finite element methods; Force; Iron; Magnetic fields; Materials; Permeability;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2011 International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4577-1044-5
Type
conf
DOI
10.1109/ICEMS.2011.6073350
Filename
6073350
Link To Document