DocumentCode :
2271396
Title :
Eddy current loss minimization in rotor magnets of PM machines using high-efficiency 12-teeth/10-slots winding topology
Author :
Dajaku, Gurakuq ; Gerling, Dieter
Author_Institution :
FEAAM GmbH, Neubiberg, Germany
fYear :
2011
fDate :
20-23 Aug. 2011
Firstpage :
1
Lastpage :
6
Abstract :
Using winding coils with different turns per coil side for the fractional slots, tooth-concentrated winding it is possible to reduce or even to cancel some space harmonics of low order resulting in lower rotor losses induced by the armature reaction field. This technique is applied to the 12-teeth/10-slots winding during investigation of the eddy current losses for two PM machines. The obtained results show that, using the new winding the magnet losses are reduced by about 80% compared with the conventional winding.
Keywords :
eddy current losses; machine windings; permanent magnet machines; eddy current loss minimization; fractional slot; permanent magnet machine; rotor magnet; space harmonics; tooth concentrated winding; winding coils; winding topology; Coils; Eddy currents; Harmonic analysis; Rotors; Stator windings; Topology; Windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2011 International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4577-1044-5
Type :
conf
DOI :
10.1109/ICEMS.2011.6073360
Filename :
6073360
Link To Document :
بازگشت