DocumentCode :
2272580
Title :
Sensitivity of the SREM RADFET dosimeters for STRV-1C to various proton and gamma radiation environments
Author :
Hajdas, Wojtek ; Bialkowski, Jacek ; Wyser, Ulrich ; Adams, Len ; Mohammadazdeh, Ali ; Nickson, Robert ; O´Connell, Barry
Author_Institution :
PSI, Villigen, Netherlands
fYear :
1999
fDate :
1999
Firstpage :
110
Lastpage :
113
Abstract :
The Standard Radiation Environment Monitor (SREM) was designed in a cooperation between ESA-ESTEC, PSI and Contraves Space-the manufacturer. The monitor detects cosmic particles using 3 direction sensitive Si detectors. Total dose measurement is performed with internal and external RADFETs located at selected positions on the satellite. Their sensitivity towards protons and gammas was characterised for various energies, dose rates and exposure geometry
Keywords :
MOSFET; dosimeters; gamma-ray detection; proton detection; radiation monitoring; readout electronics; sensitivity analysis; silicon; 3 direction sensitive Si detectors; SREM RADFET dosimeters; STRV-1C satellite; Si; Standard Radiation Environment Monitor; cosmic particles; dose rates; exposure geometry; gamma radiation environment; proton radiation environment; sensitivity; total dose measurement; Circuit testing; Degradation; Gamma rays; Geometry; Performance evaluation; Protons; Radiation monitoring; Remote monitoring; Satellites; Threshold voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radiation and Its Effects on Components and Systems, 1999. RADECS 99. 1999 Fifth European Conference on
Conference_Location :
Fontevraud
Print_ISBN :
0-7803-5726-4
Type :
conf
DOI :
10.1109/RADECS.1999.858557
Filename :
858557