Single-phase operation of a three-phase induction generator with the Smith connection
Author
Chan, T.F. ; Lai, L.L.
Author_Institution
Hong Kong Polytech. Univ., China
Volume
2
fYear
2002
fDate
2002
Abstract
Summary form only given as follows. Single-phase operation of a three-phase induction generator with the Smith connection (SMIG) is analyzed using the method of symmetrical components. It is shown that, despite the asymmetrical nature of the winding connection, balanced currents can be made to flow in the three-phase stator winding. The conditions for achieving perfect phase balance are carefully deduced. With the aid of a phasor diagram, expressions for the line power factor and line current under perfect phase balance are also obtained. The effect of the phase-balancing capacitances on the generator performance is investigated. A simple dual-mode control scheme is also proposed with a view to minimizing the phase imbalance over the practical operating speed range. Experiments conducted on a 2.2-kW induction machine confirm the validity of the theoretical analysis and feasibility of the control method.
Keywords
asynchronous generators; power factor; stators; 2.2 kW; Smith connection; balanced currents; dual-mode control scheme; line current; perfect phase balance; phase imbalance minimisation; phase-balancing capacitances; phasor diagram; power factor; single-phase operation; symmetrical components; three-phase induction generator; three-phase stator winding; Capacitance; Induction generators; Induction machines; Reactive power; Stator windings;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Society Winter Meeting, 2002. IEEE
Print_ISBN
0-7803-7322-7
Type
conf
DOI
10.1109/PESW.2002.985213
Filename
985213
Link To Document