Abstract
Fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator are described in this paper. The stator voltage is measured as well as observed. During fault free operation, the measured signal is used for the field oriented control. In case of a voltage sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Operation without measuring the stator voltage is possible. Laboratory measurements prove this concept.
Keywords
asynchronous generators; fault diagnosis; machine vector control; sensors; stators; voltage measurement; control loop reconfiguration; doubly fed induction generator; field oriented control; stator voltage measurement; voltage sensor fault detection; Fault detection; Fault diagnosis; Induction generators; Inverters; Laboratories; Observers; State estimation; Stators; Voltage control; Voltage measurement; AC generators; Observers; State estimation;