Title : 
Self-sensing comparison of fractional slot pitch winding vs. distributed winding for FW- and FI-IPMSMs based on carrier signal injection at very low speed
         
        
            Author : 
Reigosa, David ; Akatsu, Kan ; Limsuwan, Natee ; Shibukawa, Yuichi ; Lorenz, Robert D.
         
        
            Author_Institution : 
Dept.of Elec., Comput. & Syst. Eng., Univ. of Oviedo., Gijon, Spain
         
        
        
        
        
        
            Abstract : 
This paper analyzes the effects of fractional pitch and distributed winding stators on self-sensing performance of PM machines. Three rotor configurations, an FW-IPMSM and two FI-IPMSMs, and two stator designs, distributed and concentrated windings, are presented to analyze the cross-saturation, secondary saliencies, saturation-induced saliencies and saliency ratio depending on the possible rotor and stator configurations. Finite element modeling (FEM) has been used to obtain a detailed understanding of the self-sensing performance of these machines.
         
        
            Keywords : 
finite element analysis; permanent magnet machines; stators; FI-IPMSM; FW-IPMSM; PM machines; carrier signal injection; cross-saturation analysis; distributed winding stators; finite element modeling; fractional slot pitch winding; saliency ratio; saturation-induced saliencies; secondary saliencies; self-sensing comparison; Fractional slot pitch winding; Fux intensified permanent magnet synchronous machines; carrier signal injection; distributed winding; saturation effects; self-sensing;
         
        
        
        
            Conference_Titel : 
Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
         
        
            Conference_Location : 
San Jose, CA
         
        
            Print_ISBN : 
978-1-4244-2893-9
         
        
            Electronic_ISBN : 
978-1-4244-2893-9
         
        
        
            DOI : 