• DocumentCode
    2274449
  • Title

    Cleanroom Utilities Overview: University of Louisville

  • Author

    Yeager, Don

  • Author_Institution
    Center for Micro/Nanotechnol., Univ. of Louisville, Louisville, KY
  • fYear
    2008
  • fDate
    13-16 July 2008
  • Firstpage
    191
  • Lastpage
    193
  • Abstract
    Details about four major utilities that support the University of Louisville´s new Micro/NanoTechnology Cleanroom are presented. This includes a 3000 gal. deionized water system capable of delivering 18.1 Mohm-cm water at a rate of 75 gal./min., a 6,000 gal. liquid nitrogen system for delivering high purity nitrogen gas, an acid waste neutralizing system for automatically adjusting pH of cleanroom effluent, and a toxic gas monitoring system capable of monitoring over 60 satellite gas sensors.
  • Keywords
    clean rooms; environmental factors; monitoring; nanotechnology; nitrogen; N; acid waste neutralizing system; cleanroom effluent; cleanroom utilities; deionized water system; liquid nitrogen system; microtechnology cleanroom; nanotechnology cleanroom; nitrogen gas; toxic gas monitoring system; Buildings; Computerized monitoring; Effluents; Filters; Infrared sensors; Nanotechnology; Nitrogen; Remote monitoring; Sensor phenomena and characterization; Steel;