• DocumentCode
    2274557
  • Title

    Investigation of Current Sharing in Paralleled Winding at High Frequency Transformers

  • Author

    Abdi, Babak ; Milimonfared, J.

  • Author_Institution
    Islamic Azad Univ., Tehran
  • fYear
    2007
  • fDate
    6-8 Sept. 2007
  • Firstpage
    467
  • Lastpage
    471
  • Abstract
    High frequency effects and Current sharing in paralleled winding at high frequency transformers, witch are using in switch mode power supplies, will discuss in this paper. FEM method is used for simulation and shows that in ordinary paralleling winding, witch is used to decreasing of skin effect, the current is shared unbalance and for perfect paralleling of the winding, interleaved winding must be used. Also, the effect of air gap in the core on the winding current distribution will be scrutinized. And therefore, the experimental results confirm the simulation results.
  • Keywords
    finite element analysis; high-frequency transformers; switched mode power supplies; transformer windings; FEM method; current distribution; current sharing; high frequency transformers; paralleling winding; skin effect; switch mode power supplies; Conductors; Frequency; Magnetic flux; Power supplies; Skin effect; Switched-mode power supply; Switches; Switching converters; Transformer cores; Windings; HF Transformer; SMPS; current sharing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Diagnostics for Electric Machines, Power Electronics and Drives, 2007. SDEMPED 2007. IEEE International Symposium on
  • Conference_Location
    Cracow
  • Print_ISBN
    978-1-4244-1061-3
  • Electronic_ISBN
    978-1-4244-1062-0
  • Type

    conf

  • DOI
    10.1109/DEMPED.2007.4393139
  • Filename
    4393139