DocumentCode
2275381
Title
A case study of replacing steam turbines with LCI type variable speed drives
Author
Azbill, D.C. ; Catlett, R.E. ; Propst, J.E.
Author_Institution
Shell Oil Co., Houston, TX, USA
fYear
1990
fDate
7-12 Oct. 1990
Firstpage
1438
Abstract
The problems and experiences associated with the installation, startup and operation 7000, 1800 hp r/min and 3600 hp 6000 r/min synchronous motors using LCI (load commutated inverter) variable speed controllers are discussed. It is shown that, when planning the application of variable speed drives, factors such as electrical system disturbances, impact of harmonics on the existing equipment, training, commissioning, operator acceptance, craft training and spare parts need to be taken into consideration. If properly designed and installed, the drive systems provide an economical, reliable variable-speed package for petrochemical industry installations, including large critical applications.<>
Keywords
commissioning; commutation; harmonics; installation; invertors; petroleum industry; synchronous motors; variable speed drives; 3600 hp; 7000 hp; LCI; commissioning; disturbances; harmonics; installation; machine control; maintenance; petrochemical industry; spare parts; steam turbines; synchronous motors; training; variable speed drives; Commutation; Electric variables control; Fuel economy; Industrial training; Inverters; Packaging machines; Petrochemicals; Synchronous motors; Turbines; Variable speed drives;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 1990., Conference Record of the 1990 IEEE
Conference_Location
Seattle, WA, USA
Print_ISBN
0-87942-553-9
Type
conf
DOI
10.1109/IAS.1990.152374
Filename
152374
Link To Document