• DocumentCode
    2275478
  • Title

    Three-phase PFC current control using dc-rail current as feedback

  • Author

    Bing, Zhonghui ; Du, Xiong ; Sun, Jian

  • Author_Institution
    Dept. of Electr., Comput. & Syst. Eng., Rensselaer Polytech. Inst., Troy, NY, USA
  • fYear
    2009
  • fDate
    20-24 Sept. 2009
  • Firstpage
    1212
  • Lastpage
    1219
  • Abstract
    This paper presents a new current control method for three-phase power-factor-corrected (PFC) converters. The control method is a generalization to the nonlinear average current control previously developed for single-phase PFC converters, and uses only the DC-rail current as the feedback signal, avoiding the need to sense input phase currents and greatly simplifying current sensing requirements. Principle of the control method is presented first, followed by discussions of the implementation circuit and detailed design considerations. A mixed-signal implementation using an FPGA is also presented. Performance of the proposed control method is demonstrated by measurement results from a 2 kW prototype operating with both 60 Hz and high-frequency (400-800 Hz) lines.
  • Keywords
    electric current control; field programmable gate arrays; power convertors; power factor correction; DC-rail current; FPGA; feedback signal; frequency 400 Hz to 800 Hz; frequency 60 Hz; high-frequency lines; mixed-signal implementation; nonlinear average current control; power 2 kW; single-phase PFC converters; three-phase PFC current control; three-phase power-factor-corrected converters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
  • Conference_Location
    San Jose, CA
  • Print_ISBN
    978-1-4244-2893-9
  • Electronic_ISBN
    978-1-4244-2893-9
  • Type

    conf

  • DOI
    10.1109/ECCE.2009.5316148
  • Filename
    5316148