Abstract :
A multifunction Giga hertz Transverse Electromagnetic (GTEM) cell is presented for radiated EMI mechanism diagnosis in this paper. The structure design and measurement principle of the cell are discussed, in the meanwhile, the radiated EMI noise mechanism diagnosis by using GTEM cell is applied for equipment under test (EUT). The multi-pole moment model is employed in GTEM cell to realize EMI measurement and the near filed mechanism diagnosis setup is used to decide whether the dominate noise is common-mode (CM) or differential-mode (DM) noise. The experimental results show that the proposed multifunction GTEM cell can not only be utilized for radiated EMI measurement, but also be effective for mechanism diagnosis.
Keywords :
TEM cells; electromagnetic interference; equipment evaluation; noise measurement; EMI noise mechanism diagnosis; common mode noise; differential mode noise; equipment under test; multifunction GTEM cell; multifunction gigahertz transverse electromagnetic cell; multipole moment model; near filed mechanism diagnosis setup; radiated EMI measurement; Electromagnetic compatibility; Electromagnetic interference; Frequency measurement; Impedance; Magnetic field measurement; Noise; TEM cells; EM measurement; Giga hertz Transverse Electromagnetic (GTEM); electromagnetic interference (EMI); multi-pole model; noise mechanism diagnosis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Power and Energy Conference (EPEC), 2010 IEEE
Conference_Location :
Halifax, NS
Print_ISBN :
978-1-4244-8186-6
Type :
conf
DOI :
10.1109/EPEC.2010.5697170
Filename :
5697170
Link To Document :
بازگشت