  • Abstract
    We report on the development of a compact Cs cell CPT frequency standard operating in the Dicke regime. Combining a double Lambda scheme and a Ramsey interrogation, high contrast fringes whose linewidth depends on the time separating two pulses, are obtained. Compared to the continuous regime, the pulsed interrogation reduces the light shift by a factor 300 and permits to reach frequency stability 10 times better. A frequency stability of 9.10-13 at 1 s has already been measured.
  • Keywords
    atomic clocks; frequency standards; laser frequency stability; radiation pressure; Dicke regime; Ramsey interrogation; compact pulsed CPT caesium clock; contrast fringes; double Lambda scheme; frequency stability; frequency standard; pulsed interrogation; Atomic beams; Clocks; Frequency; Gas lasers; Laser beams; Laser excitation; Laser noise; Masers; Stability; Stationary state;