DocumentCode :
2276402
Title :
Testing to assure reliable operation of electric motors
Author :
Schump, David E.
Author_Institution :
Baker Instrum. Co., Fort Collins, CO, USA
fYear :
1990
fDate :
7-12 Oct. 1990
Firstpage :
1478
Abstract :
Several field test procedures that can be used as part of a motor maintenance program to insure reliable operation of electric motors in large integrated process plants are discussed. Different types of motor electrical insulation systems are reviewed, and their failure mechanisms are described.<>
Keywords :
electric motors; insulation testing; machine insulation; machine testing; maintenance engineering; electric motors; electrical insulation systems; failure mechanisms; integrated process plants; maintenance; operational reliability; testing; Electric motors; Failure analysis; Inductors; Insulation; Maintenance; Polymers; Temperature; Testing; Thermal stresses; Wounds;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Society Annual Meeting, 1990., Conference Record of the 1990 IEEE
Conference_Location :
Seattle, WA, USA
Print_ISBN :
0-87942-553-9
Type :
conf
DOI :
10.1109/IAS.1990.152379
Filename :
152379
Link To Document :
بازگشت