• DocumentCode
    2276652
  • Title

    Analysis of the breakdown fault in field voltage withstand test of 500kV SF6 current transformer

  • Author

    Yongji Zhang ; Yongming Wang ; Haitao Huang ; Guoshun Zheng ; Zhijin Zhang

  • Author_Institution
    Maintenance Branch Co., Fujian Electr. Power Co. Ltd., China
  • fYear
    2012
  • fDate
    17-20 Sept. 2012
  • Firstpage
    518
  • Lastpage
    522
  • Abstract
    Current transformer, the major primary equipment in power system, can transform a large primary current into the standard 5A or 1A current. It provides current for the measure device and the coil of relay protection, meanwhile makes the primary equipments isolate from the secondary equipments. With the development of grid, SF6 current transformers have been widely used. Once the fault of the internal insulation support in SF6 current transformer appears, it will threat the safe operation of power systems. In recent years, the fault accidents of current transformer have occurred form time to time. This paper introduces the fault conditions of 500kv current transformer in the area under the jurisdiction of Xiamen EHV Power Transmission and Transformation Bureau. After it be sent back to factory and disassembled, we found that many large area of paint have come off the inner surface of shell of the current transformer, and that there many blister on the inner surface of shell. Meanwhile, send the same batch transformers back to the factory and disassemble, we found that there are many problems in the production process. So this paper suggests that the production process of SF6 current transformer should be monitored. And after it has been installed, we have to do the aging test and voltage withstand test. To prevent the same fault of 500kv current transformer occurs again, the results in this paper can give some reference and engineering application consult.
  • Keywords
    current transformers; power systems; power transmission; transformer insulation; Xiamen EHV Power Transmission and Transformation Bureau; aging test; breakdown fault analysis; current 1 A; current 5 A; current transformer; internal insulation; power systems; primary current; primary equipments; relay protection coil; secondary equipments; voltage 500 kV; voltage withstand test; Circuit faults; Current transformers; Paints; Substations; Sulfur hexafluoride; Surface treatment;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High Voltage Engineering and Application (ICHVE), 2012 International Conference on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4673-4747-1
  • Type

    conf

  • DOI
    10.1109/ICHVE.2012.6357040
  • Filename
    6357040