Study on the calibration of partial discharge calibrator
Author :
Na, Liu ; Zhi, Li ; Zheng, Qian
Author_Institution :
Electr. Magn. Div., Nat. Inst. of Metrol., Beijing
fYear :
2008
fDate :
8-13 June 2008
Firstpage :
232
Lastpage :
233
Abstract :
The calibration of apparent charge, which can be traced to AC voltage and capacitance, for partial discharge(PD) calibrator is discussed. The methods of fast sampling measurement of peak-to-peak amplitude for step voltage by digital multimeter and the arithmetic in the automatic measurement of apparent charge by digital oscilloscope are focused on. Then, other factors, such as impulse waveform and the choice of capacitor are also discussed.
Keywords :
calibration; digital multimeters; oscilloscopes; partial discharge measurement; digital multimeter; digital oscilloscope; partial discharge calibrator; sampling measurement; Calibration; Capacitance; Charge measurement; Current measurement; Digital arithmetic; Oscilloscopes; Partial discharge measurement; Partial discharges; Sampling methods; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location :
Broomfield, CO
Print_ISBN :
978-1-4244-2399-6
Electronic_ISBN :
978-1-4244-2400-9
Type :
conf
DOI :
10.1109/CPEM.2008.4574738