Abstract :
Recently, permanent magnet synchronous motors are applied to various applications such as electric vehicle, aerospace, medical service, and military applications due to several outstanding characteristics. Because of the importance of high reliable operation in these areas, many researches which are related to the fault detection and diagnosis of inverter systems are conducted. In this paper, a new simple fault detection method of voltage source inverter for permanent magnet synchronous motor is proposed. The feasibility of the proposed method is proved by simulation and experiment. By the simulation and experiments, rapid detection characteristic of the proposed method has been proved without any additional voltage sensor.
Keywords :
fault diagnosis; invertors; permanent magnet motors; synchronous motors; fault diagnosis; permanent magnet synchronous motors; switch open fault detection; voltage source inverter; FDD; fault detection; switch open fault; voltage source inverter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
Conference_Location :
San Jose, CA
Print_ISBN :
978-1-4244-2893-9
Electronic_ISBN :
978-1-4244-2893-9
Type :
conf
DOI :
10.1109/ECCE.2009.5316260
Filename :
5316260
Link To Document :
بازگشت