• DocumentCode
    2277895
  • Title

    Comparision scattering coefficient measurements by broad-band methods from 2 — 18 GHz using type N connectors

  • Author

    Eio, C.

  • Author_Institution
    Nat. Phys. Lab., Teddington
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    256
  • Lastpage
    257
  • Abstract
    This paper presents the results of GT-RF international key comparison CCEM.RF-K5b.CL for the measurement of scattering coefficients over the range of 2-18 GHz. Nineteen National Metrology Institutes were involved in this comparison, which took place between June 2003 and November 2006. On the whole, the results show a good agreement amongst the participants.
  • Keywords
    electric connectors; electromagnetic wave scattering; measurement systems; GT-RF international key comparison CCEM.RF-K5b.CL; broad-band methods; frequency 2 GHz to 18 GHz; scattering coefficient measurements; travelling standards; type n connectors; Attenuators; Connectors; Laboratories; Measurement standards; Measurement uncertainty; Metrology; Particle measurements; Performance analysis; Performance evaluation; Scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574750
  • Filename
    4574750